Data Logger and Sensor Interface C 80

We offer the C 80 in two basic versions, on the one hand as a data logger and on the other hand as a sensor interface. Choose between these basic variants and combine or add functionalities now or later.

The data logger C 80 is a professional data logging system for motorsport applications. This allows for synchronized acquisition of engine data from the ECU and chassis data from up to 26 analog and 4 digital input channels. Additional input devices can be connected via Ethernet and CAN buses.

Recorded data from the up to 16 GB logger can be downloaded via high speed Ethernet.

Software upgrades for the C 80 (field upgradable by entering a key) activate tailored configurations like a second logging partition of 4 GB, USB recording, CCP/XCP-master for simple data access to third party devices, as well as additional input channels.

Features

  • Aluminum housing
  • Powerful data logger with up to 20 GB memory
  • Supports Bosch multi-logger configuration
  • USB recording and full telemetry support

Application

Converters

10 kHz 12 bit AD converters with digital low pass filter

Configurable math channels

User configurable CAN in/out messages

Sampling rate

Max. 1,000 Hz for all channels

Online data compression

 

Logging rate

600 kB/s with FULL_LOG_1,
800 kB/s with FULL_LOG_1 & PERF_LOG_1

Recording channels

Up to 1,440

Logged data download speed

Max. 1,000 kB/s

Internal storage capacity

Partition 1:
4 GB with FULL_LOG_1,
16 GB with FULL_LOG_1 & PERF_LOG_1

Partition 2:
additional 4 GB with FULL_LOG_2

3-port network switch

 

Telemetry Support via Ethernet (recommended) and RS232

RS232 GPS input

 

CCP/XCP-Master, data acquisition from ECU that support CAN calibration protocol (optional)

Technical Specifications

Mechanical Data

Size

105 x 34.5 x 137.5 mm

Weight

462 g

Protection Classification

IP67 to DIN 40050, Section 9, Issue 2008

Max. vibration

Vibration profile 1 (see Appendix or www.bosch-motorsport.com)

Operating temperature (internal)

0 to 85°C

Operation outside the temperature limits can be tested on request during the manufacturing tests.

Electrical Data

Supply voltage

8 to 18 V

Max. power consumption (w/o loads)

10 W at 14 V

Inputs

Analog channels

6

Input range

0 to 5 V

Resolution

12 bit

Switchable pull up resistor

3 kOhm

Outputs

PWM outputs (low side switch 2 A each)

4

Sensor supply 5 V ± 1 % (250 mA)

1

Environment

Software Upgrade CCP_MASTER / XCP_MASTER

CCP/XCP-Master (ASAP 2 file from ECU manufacturer required)

Software Upgrade FULL_LOG_1 (included in C 80 Logger)

Enable logging partition 1 with 4 GB memory, 600 kB/s (666 MHz)

Software Upgrade PERF_LOG_1 (requires FULL_LOG_1)

Increase logging partition 1 from 4 GB to 16 GB memory, 800 kB/s (866 MHz)

Software Upgrade FULL_LOG_2

Enable logging partition 2 with 4 GB memory. Ideally for protected access by different teams or to use as long-term logger.

Software Upgrade I_O EXTENS (included in C 80 Sensor Interface)

Additional analog channels

20

Rotational channels (input Hall/inductive)

4

Additional sensor supply 5 V (250 mA each)

3

Sensor supply 10 V (250 mA)

1

Sensor supply 12 V (1 A), non-regulated

1

RS232

GPS

USB Kit

Rugged USB flash drive Bosch File System (BFS) format included, works with BFS preformatted USB flash drive only

Adapter cable to USB-Port

Adapter for wiring harness

SW license USB-Port unlocked

Connectors and Wires

Motorsport connectors double density

2 x 41 pins

Mating connector I
ASDD612-41SN

F02U.002.216-01

Mating connector II
ASDD612-41SA

F02U.004.180-01

Pin Layout ASDD212-41PN

Pin

Name

Description

1

KL30

 

2; 3

KL15

 

4; 5

KL31

 

6

Ethernet Channel0 Tx plus

Wire Ethernet_0 - TX+

7

Ethernet Channel0 Tx minus

Wire Ethernet_0 - TX-

8

Ethernet Channel0 Rx plus

Wire Ethernet_0 - RX+

9

Ethernet Channel0 Rx minus

Wire Ethernet_0 - RX-

10

Ethernet Schirm

Ethernet Schirm

11

Ethernet Channel1 Tx plus

Wire Ethernet_0 - TX+

12

Ethernet Channel1 Tx minus

Wire Ethernet_0 - TX-

13

Ethernet Channel1 Rx plus

Wire Ethernet_0 - RX+

14

Ethernet Channel1 Rx minus

Wire Ethernet_0 - RX-

15

Ethernet Channel2 Tx plus

Wire Ethernet_0 - TX+

16

Ethernet Channel2 Tx minus

Wire Ethernet_0 - TX-

17

Ethernet Channel2 Rx plus

Wire Ethernet_0 - RX+

18

Ethernet Channel2 Rx minus

Wire Ethernet_0 - RX-

19

CAN_A_H

CAN_A - HIGH

20

CAN_A_L

CAN_A - LOW

21

CAN_B_H

CAN_B - HIGH

22

CAN_B_L

CAN_B - LOW

23

USB Power

500mA USB_Power

24

USB Data Plus

USB_OTG_Plus

25

USB Data Minus

USB_OTG_Minus

26

USB GND

USB_Ground

27

SENSPWR5_1

 

28

SENSGND

 

29

Timestamp

 

30

LS_GND_1

Low-Side Ground2

31

LS_SWITCH_1

lowside switch 2A

32

LS_SWITCH_2

lowside switch 2A

33

LS_SWITCH_3

lowside switch 2A

34

LS_SWITCH_4

lowside switch 2A

35

LS_GND_2

Low-Side Ground2

36

ANAIN_M1_1

0 to 5V Analog

37

ANAIN_M1_2

0 to 5V Analog

38

ANAIN_M1_3

0 to 5V Analog

39

ANAIN_M1_4

0 to 5V Analog

40

ANAIN_M1_5

0 to 5V Analog

41

ANAIN_M1_6

0 to 5V Analog

Pin Layout ASDD212-41PA

Pin

Name

Description

1

UBATT_FUSE1

 

2

SENSPWR10_1

 

3

SENSPWR5_2

 

4

SENSPWR5_3

 

5

SENSPWR5_4

 

6; 7

SENSGND

 

8

RS232A TX

RS232A - Transmit

9

RS232A RX

RS232A - Receive

10

RS232B TX

RS232B - Transmit

11

RS232B RX

RS232B - Receive

12

RS232_GND

RS232_GND

13

REV1_P

DHE I/P or Inductive - KW+

14

REV1_M

DHE I/P or Inductive - KW-

15

REV2_P

DHE I/P or Inductive - KW+

16

REV2_M

DHE I/P or Inductive - KW-

17

REV3_P

DHE I/P or Inductive - KW+

18

REV3_M

DHE I/P or Inductive - KW-

19

REV4_P

DHE I/P or Inductive - KW+

20

REV4_M

DHE I/P or Inductive - KW-

21

ANAIN_M1_7

0 to 5V Analog

22

ANAIN_M1_8

0 to 5V Analog

23

ANAIN_M1_9

0 to 5V Analog

24

ANAIN_M1_10

0 to 5V Analog

25

ANAIN_M1_11

0 to 5V Analog

26

ANAIN_M1_12

0 to 5V Analog

27

ANAIN_M1_13

0 to 5V Analog

28

ANAIN_M1_14

0 to 5V Analog

29

ANAIN_M1_15

0 to 5V Analog

30

ANAIN_M1_16

0 to 5V Analog

31

ANAIN_M2_1

0 to 5V Analog

32

ANAIN_M2_2

0 to 5V Analog

33

ANAIN_M2_3

0 to 5V Analog

34

ANAIN_M2_4

0 to 5V Analog

35

ANAIN_M2_5

0 to 5V Analog

36

ANAIN_M2_6

0 to 5V Analog

37

ANAIN_M2_7

0 to 5V Analog

38

ANAIN_M2_8

0 to 5V Analog

39

ANAIN_M2_9

0 to 5V Analog

40

ANAIN_M2_10

0 to 5V Analog

41

LAPTRIGGER

 

Communication

Configuration via RaceCon over Ethernet or MSA-Box II

CAN interfaces

2

Ethernet 100BaseT

3

Telemetry

Ethernet or RS232

Lap trigger input

1

Installation Notes

Inspection services recommended after 220 h or 2 years, no components to replace.

Depending on your experience calibrating Bosch ECUs, we recommend calibration support from Bosch Motorsport.

Please remember that the mating connectors and the programming interface MSA Box II are not included and must be ordered separately.

Not reverse polarity protected on supply or outputs.

Software

The required software (.pst file) for this device is available in the download area of our homepage www.bosch-motorsport.com.

Download data and save configurations before sending device as it will be reset during service.

Ordering Information

C 80 Logger

FULL_LOG_1 included

Order number: F02U.V03.083-01

C 80 Sensor Interface

I_O EXTENS included

Order number: F02U.V03.082-01

Software Options

CCP_MASTER / XCP_MASTER

Order number: F02U.V02.213-01

FULL_LOG_1

Order number: F02U.V02.304-01

FULL_LOG_2

Order number: F02U.V02.305-01

IO_EXTENS

Order number: F02U.V02.205-01

ADV_TELEM

Order number: tbd.

PERF_LOG_1

Order number: F02U.V03.054-01

Accessories

USB Kit

Order number: F02U.V02.214-01

Downloads