Data Logger C 70
Product Highlights
Features
- Cutting-edge 667 MHz Dual Core Processor
- Recording on USB flash drive (opt.)
- Supports GPS lap trigger, pre-dated lap time etc.
- High programming flexibility using mathematical functions and conditional channels
Downloads
Literature
Software
Product Details
Application
|
Processor
|
667 MHz Dual Core
|
|
Processor
Converters
|
667 MHz Dual Core
10 kHz 12 bit AD converters with digital low pass filter
|
|
Processor
Internal power source
|
667 MHz Dual Core
Li/Ion capacitor
|
|
Processor
Configurable math channels
|
667 MHz Dual Core
|
|
Processor
User configurable CAN in/out messages
|
667 MHz Dual Core
|
|
Processor
Online data compression
|
667 MHz Dual Core
|
|
Processor
Internal logger
|
667 MHz Dual Core
|
|
Processor
Logging rates
|
667 MHz Dual Core
|
|
Processor
LTE Ethernet telemetry support, GSM telemetry support
|
667 MHz Dual Core
|
Technical Specification
|
Mechanical Data
|
|
|
Mechanical Data
Size
|
151 x 126 x 25.5 mm
|
|
Mechanical Data
Weight
|
450 g
|
|
Mechanical Data
Protection Classification
|
IP54 to DIN 40050, Section 9, Issue 2008
|
|
Mechanical Data
Operating temperature internal
|
-20 to 85°C
|
|
Mechanical Data
Max. vibration
|
Vibration profile 1 (see Downloads or www.bosch-motorsport.com)
|
|
Electrical Data
|
|
|
Electrical Data
Supply voltage
|
5 to 18 V
|
|
Inputs
|
|
Inputs
4 x analog channels, additional 12 optional
|
|
Inputs
0 to 5 V input range
|
|
Inputs
12 bit resolution
|
|
Inputs
switchable pull up resistor for all ANA_IN
|
|
Inputs
4 x Hall-effect or DF11 wheel speed inputs, switchable
|
|
Sensor Supplies and Screens
|
|
Sensor Supplies and Screens
2 x Sensor supply 5 V ± 1 % (250 mA)
|
|
Sensor Supplies and Screens
1 x Sensor supply 10 V ± 1 % (250 mA)
|
|
Sensor Supplies and Screens
1 x Sensor supply U_Bat (250 mA)
|
|
Sensor Supplies and Screens
4 x Sensor ground
|
|
Connectors and Wires
|
|
|
Connectors and Wires
Motorsport connector on logger
|
AS216-35PN
|
|
Connectors and Wires
Mating connector
AS616-35SN |
F02U.000.466-01
|
|
Pin Configuration
|
|
|
|
|
Pin Configuration
Pin
|
Name
|
Comment
|
Status
|
|
Pin Configuration
1
|
KL_31
|
|
Incl.
|
|
Pin Configuration
2
|
KL_15
|
|
Incl.
|
|
Pin Configuration
3
|
KL_30
|
|
Incl.
|
|
Pin Configuration
4
|
Rev_In_3
|
Hall or DF11 switchable
|
Incl.
|
|
Pin Configuration
5
|
Rev_In_1
|
Hall or DF11 switchable
|
Incl.
|
|
Pin Configuration
6
|
KL_31
|
|
Incl.
|
|
Pin Configuration
7
|
CAN_2_L
|
CAN speed selectable
|
Incl.
|
|
Pin Configuration
8
|
Ethernet_2_TXP
|
|
Incl.
|
|
Pin Configuration
9
|
Ethernet_2_TXN
|
|
Incl.
|
|
Pin Configuration
10
|
Sens_Power_12V
|
over current protected
|
Incl.
|
|
Pin Configuration
11
|
Rev_In_4
|
Hall or DF11 switchable
|
Incl.
|
|
Pin Configuration
12
|
Rev_In_2
|
Hall or DF11 switchable
|
Incl.
|
|
Pin Configuration
13
|
Laptrigger_In
|
|
Incl.
|
|
Pin Configuration
14
|
CAN_2_H
|
CAN speed selectable
|
Incl.
|
|
Pin Configuration
15
|
CAN_1_H
|
CAN speed selectable
|
Incl.
|
|
Pin Configuration
16
|
Ethernet_2_RXP
|
|
Incl.
|
|
Pin Configuration
17
|
Sens_Gnd_4
|
fused
|
Incl.
|
|
Pin Configuration
18
|
Sens_Power 5V
|
over current protected
|
Incl.
|
|
Pin Configuration
19
|
ANA_IN_3
|
3.01 kOhm switchable
|
Incl.
|
|
Pin Configuration
20
|
ANA_IN_4
|
3.01 kOhm switchable
|
Incl.
|
|
Pin Configuration
21
|
Time_Sync
|
connection to Bosch ECU
|
Incl.
|
|
Pin Configuration
22
|
CAN_1_L
|
CAN speed selectable
|
Incl.
|
|
Pin Configuration
23
|
Com_screen
|
Ethernet and USB screen
|
Incl.
|
|
Pin Configuration
24
|
Ethernet_2_RXN
|
|
Incl.
|
|
Pin Configuration
25
|
Sens_Gnd_3
|
fused
|
Incl.
|
|
Pin Configuration
26
|
Sens_Power 5V
|
over current protected
|
Incl.
|
|
Pin Configuration
27
|
ANA_IN_7
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
28
|
ANA_IN_1
|
3.01 kOhm switchable
|
Incl.
|
|
Pin Configuration
29
|
USB_Device_DP
|
to Bosch USB stick
|
Opt.
|
|
Pin Configuration
30
|
RS232_TX_Telemetry
|
Transmit Telemetry data
|
Incl.
|
|
Pin Configuration
31
|
Ethernet_1_TXP
|
|
Incl.
|
|
Pin Configuration
32
|
Sens_Gnd_2
|
fused
|
Incl.
|
|
Pin Configuration
33
|
Sens_Power_10V
|
over current protected
|
Incl.
|
|
Pin Configuration
34
|
ANA_IN_8
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
35
|
ANA_IN_10
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
36
|
USB_Device_Gnd
|
to Bosch USB stick
|
Opt.
|
|
Pin Configuration
37
|
USB_Device_DN
|
to Bosch USB stick
|
Opt.
|
|
Pin Configuration
38
|
RS232_RX_Telemetry
|
Receive Telemetry data
|
Incl.
|
|
Pin Configuration
39
|
Ethernet_1_TXN
|
|
Incl.
|
|
Pin Configuration
40
|
Sens_Gnd_1
|
fused
|
Incl.
|
|
Pin Configuration
41
|
ANA_IN_11
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
42
|
ANA_IN_9
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
43
|
RS232_TX_GPS
|
Transmit GPS data
|
Incl.
|
|
Pin Configuration
44
|
ANA_IN_16
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
45
|
USB_Device_Power
|
to Bosch USB stick
|
Opt.
|
|
Pin Configuration
46
|
Ethernet_1_RXP
|
|
Incl.
|
|
Pin Configuration
47
|
ANA_IN_12
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
48
|
ANA_IN_6
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
49
|
ANA_IN_2
|
3.01 kOhm switchable
|
Incl.
|
|
Pin Configuration
50
|
ANA_IN_13
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
51
|
ANA_IN_15
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
52
|
Ethernet_1_RXN
|
|
Incl.
|
|
Pin Configuration
53
|
ANA_IN_5
|
3.01 kOhm switchable
|
Opt.
|
|
Pin Configuration
54
|
RS232_RX_GPS
|
Receive GPS data
|
Incl.
|
|
Pin Configuration
55
|
ANA_IN_14
|
3.01 kOhm switchable
|
Opt.
|
Dimensions
Further Information
Communication
|
CAN interfaces
|
2
|
|
CAN interfaces
Ethernet 100BaseT
|
2
2
|
|
CAN interfaces
Laptrigger input
|
2
1
|
|
CAN interfaces
RS232
|
2
Telemetry, GPS
|
|
CAN interfaces
Configuration via RaceCon
|
2
Over Ethernet or MSA-Box II
|
Installation Notes
|
Maintenance Interval: 220 h or a maximum of two years
|
Ordering Information
Data Logger C 70
Order number: F02U.V02.302-02
Rugged USB flash drive
Order number: F02U.V03.534-01
Connector for USB flash drive on car loom side
Order number: F02U.002.996-01
Adapter cable to PC USB-Port
Order number: F02U.V01.343-01
Software Options
CCP/XCP_MASTER
Order number: F02U.V02.213-01
FULL_LOG_2
Order number: F02U.V02.305-01
IO_EXTENS
Order number: F02U.V02.205-01
DATA_USB
Order number: F02U.V03.476-01
Accessories
Vehicle Loom Basic
Order number: F02U.V02.735-01
Bench Loom
Order number: F02U.V02.349-01
Upgrades
|
CCP/XCP_MASTER
|
|
CCP/XCP_MASTER
Enables CCP/XCP master functionality to request data from foreign devices via CAN/CCP protocol or XCP over Ethernet (UDP).
(ASAP2 file from ECU manufacturer required) |
|
FULL_LOG_2
|
|
FULL_LOG_2
4 GB memory on Partition 2
|
|
IO_EXTENS
|
|
IO_EXTENS
Additional 12 analog input channels
|
|
DATA_USB
|
|
DATA_USB
Data copy to USB flash drive
|
Legal Restrictions
Generally blocked are direct and indirect business involving high risk destinations, including Russia, Belarus, Cuba, Iran, North Korea, Syria, Libya, Afghanistan, and certain non-governmental controlled Ukrainian regions. This list may change as geopolitics evolve.