Lambdatronic LT4 ADV
Product Highlights
Features
- Supply of up to 4 Bosch lambda sensors, type LSU ADV
- Integrated voltage compensation for sensor heater
Downloads
Product Details
Application
|
Application
|
Lambda 0.75 to 5
|
|
Application
Compatible Bosch sensor type
|
Lambda 0.75 to 5
LSU ADV
|
|
Application
Channels
|
Lambda 0.75 to 5
4
|
|
Application
Heater
|
Lambda 0.75 to 5
Internal
|
Technical Specification
|
Mechanical Data
|
|
|
Mechanical Data
Weight with wire
|
98 g
|
|
Mechanical Data
Sealing
|
100 % humidity
|
|
Mechanical Data
Mounting
|
Velcro
|
|
Mechanical Data
Size w/o wire (w*l*h)
|
54 x 59 x 13 mm
|
|
Mechanical Data
Operating temp. range (housing)
|
-20 to 85°C
|
|
Mechanical Data
Storage temp. range
|
-20 to 85°C
|
|
Mechanical Data
Max. vibration
|
Vibration Profile 1
|
|
Electrical Data
|
|
|
Electrical Data
Power supply US
|
(6.5) 10 to 14 V
|
|
Electrical Data
Max power supply (1 min) US
|
Max. 26 V
|
|
Electrical Data
Thermal dissipation loss
|
3 W at 14 V
|
|
Electrical Data
Current Is
|
5 A
|
|
Electrical Data
Current Is (Heating up)
|
26 A
|
|
Software Tool (free download)
|
|
Software Tool (free download)
System Configuration tool RaceCon 2.7.0.9 or later
|
|
Characteristic
|
|
|
Characteristic
Signal output 1
|
CAN
|
|
Characteristic
Signal output 2
|
4 x 0 to 5 V “analog”
|
|
Characteristic
CAN- baud rate
|
500 kbaud or 1 Mbaud
|
|
Characteristic
Signal resolution
|
2,5 * 10-4 lambda
|
|
Characteristic
Signal sampling rate
|
100 Hz
|
|
Characteristic
CAN refresh rate
|
100 Hz
|
|
Connectors and Wires
|
|
|
Connectors and Wires
Connector
|
AS614-35PN
|
|
Connectors and Wires
Connector loom
AS114-35SN |
F02U.000.365-01
|
|
Connectors and Wires
Sleeve
|
Viton
|
|
Connectors and Wires
Wire size
|
26
|
|
Connectors and Wires
Wire length L
|
20 cm
|
|
Pin Assignment
|
|
|
Pin Assignment
Pin
|
Function
|
|
Pin Assignment
1
|
+ 12 V (Battery +)
|
|
Pin Assignment
2
|
+ 12 V (Battery +)
|
|
Pin Assignment
3
|
Ground (Battery -)
|
|
Pin Assignment
4
|
Ground (Battery -)
|
|
Pin Assignment
5
|
K-Line diagnostic connection
|
|
Pin Assignment
6
|
CAN1 + (high)
|
|
Pin Assignment
7
|
CAN1 - (low)
|
|
Pin Assignment
8
|
Analog out 1
|
|
Pin Assignment
9
|
Analog out 2
|
|
Pin Assignment
10
|
Analog out 3
|
|
Pin Assignment
11
|
Analog out 4
|
|
Pin Assignment
12
|
Reference GND for analog out
|
|
Pin Assignment
13
|
Shield
|
|
Pin Assignment
14
|
Pump current LSU 1 IP1
|
|
Pin Assignment
15
|
Virtual GND LSU 1 VM1
|
|
Pin Assignment
16
|
Heater PWM LSU 1 Uh-1
|
|
Pin Assignment
17
|
Heater (Batt +) LSU 1 Uh+1
|
|
Pin Assignment
18
|
Not connected
|
|
Pin Assignment
19
|
Nernst voltage LSU 1 UN1
|
|
Pin Assignment
20
|
Pump current LSU 2 IP2
|
|
Pin Assignment
21
|
Virtual GND LSU 2 VM2
|
|
Pin Assignment
22
|
Heater PWM LSU 2 Uh-2
|
|
Pin Assignment
23
|
Heater (Batt. +) LSU 2 Uh+2
|
|
Pin Assignment
24
|
Not connected
|
|
Pin Assignment
25
|
Nernst voltage LSU 2 UN2
|
|
Pin Assignment
26
|
Pump current LSU 3 IP3
|
|
Pin Assignment
27
|
Virtual GND LSU 3 VM3
|
|
Pin Assignment
28
|
Heater PWM LSU 3 Uh-3
|
|
Pin Assignment
29
|
Heater (Batt +) LSU 3 Uh+3
|
|
Pin Assignment
30
|
Not connected
|
|
Pin Assignment
31
|
Nernst voltage LSU 3 UN3
|
|
Pin Assignment
32
|
Pump current LSU 4 IP4
|
|
Pin Assignment
33
|
Virtual GND LSU 4 VM4
|
|
Pin Assignment
34
|
Heater PWM LSU 4 Uh-4
|
|
Pin Assignment
35
|
Heater (Batt. +) LSU 4 Uh+4
|
|
Pin Assignment
36
|
Not connected
|
|
Pin Assignment
37
|
Nernst voltage LSU 4 UN4
|
Dimensions
Further Information
Communication
|
Communication link
|
K-Line / CAN
|
Installation Notes
|
Typical lifetime: max. 220 h / 2 years
|
|
Typical lifetime: max. 220 h / 2 years
For application with severe conditions and/or high volume, please contact your Bosch Motorsport counterpart in order to define the most appropriate validation program
|
|
Typical lifetime: max. 220 h / 2 years
The LT4 ADV is designed to supply 4 Bosch lambda sensors, type LSU ADV
|
|
Typical lifetime: max. 220 h / 2 years
The LT4 ADV is featured with voltage compensation for the heating profile.
|
|
Typical lifetime: max. 220 h / 2 years
The unit can be connected to any CAN system (500 kbaud or 1 Mbaud) and analog measuring device.
|
|
Typical lifetime: max. 220 h / 2 years
To avoid signal errors, a cable length of maximum 1.5 m between sensor and box is recommended.
|
|
Typical lifetime: max. 220 h / 2 years
The unit is secure from miss-pinning.
|
|
Typical lifetime: max. 220 h / 2 years
The reference ground (GND_REF) has to be connected either to the measuring device or to the system ground.
|
|
Typical lifetime: max. 220 h / 2 years
A ground offset of 2 V (max.) between GND and GND_REF has not to be exceeded.
|
|
Typical lifetime: max. 220 h / 2 years
See the LT4 ADV function sheet for software documentation (e.g. CAN protocol).
|
|
Typical lifetime: max. 220 h / 2 years
Please find further application hints in the offer drawing at our homepage.
|
Ordering Information
Lambdatronic LT4 ADV
Order number: F02U.V01.111-04
Legal Restrictions
Generally blocked are direct and indirect business involving high risk destinations, including Russia, Belarus, Cuba, Iran, North Korea, Syria, Libya, Afghanistan, and certain non-governmental controlled Ukrainian regions. This list may change as geopolitics evolve.