Fuel Pump FP 200-7
Product Highlights
Features
- >200 l/h
- Internal pressure limiting valve
- 750 g
- Fuel lines screwed
- Internal pre-filter on suction side with 300 µm
Downloads
Literature
Product Details
Application
|
Fuel pressure
|
Up to 7,5 bar
|
|
Fuel pressure
Gasoline delivery rate at 5 bar and 22°C
|
Up to 7,5 bar
>220 to 270 l/h
|
|
Fuel pressure
Diesel delivery rate at 7 bar and 22°C
|
Up to 7,5 bar
>185 to 235 l/h
|
|
Fuel pressure
Pressure limiting valve
|
Up to 7,5 bar
8,0 to 10,0 bar
|
|
Fuel pressure
Gasoline compatibility
|
Up to 7,5 bar
Up to E10
|
|
Fuel pressure
Diesel compatibility
|
Up to 7,5 bar
Given
|
|
Fuel pressure
Operating temperature range
|
Up to 7,5 bar
-40 to 80°C
≤90°C for ≤5 h over 1.000 h lifetime ≤105°C for ≤1 h over 50 h lifetime |
|
Fuel pressure
Storage temperature range
|
Up to 7,5 bar
-30 to 60°C
|
|
Fuel pressure
Max. vibration
IEC 60068-2-34 |
Up to 7,5 bar
10 Hz 19,4 (m/s2)2/Hz
300 Hz 0,654 (m/s2)2/Hz 1.000 Hz 0,059 (m/s2)2/Hz |
Technical Specification
|
Mechanical Data
|
|
|
Mechanical Data
Diameter
|
60 mm
|
|
Mechanical Data
Length
|
197 mm
|
|
Mechanical Data
Weight
|
750 g
(864 g incl. cable kit) |
|
Mechanical Data
Mounting
|
Clamping
|
|
Electrical Data
|
|
|
Electrical Data
Supply voltage
|
6 to 15 V (26 V for 60 s)
|
|
Electrical Data
Operating voltage
|
13 V
|
|
Electrical Data
Load current at 5 bar and 22°C
|
≤ 17 A
|
|
Characteristic
|
|
|
Characteristic
Color
|
Silver
|
|
Characteristic
Non-return valve
|
External
|
|
Characteristic
Fuel filtering
|
External, on pressure side
|
|
Characteristic
Over-pressure valve
|
Internal
|
|
Connectors and Wires
|
|
|
Connectors and Wires
Electrical connector
|
+M4/-M5
|
|
Connectors and Wires
Electrical mating connector
|
With ring wire M4 and M5
|
|
Connectors and Wires
Mechanical connector intake side
|
M18x1.5
|
|
Connectors and Wires
Mechanical connector pressure side
|
M12x1.5
|
Dimensions
Further Information
Installation Notes
|
Up to E100 with shorter lifetime
|
|
Up to E100 with shorter lifetime
For technical reasons the values may vary.
|
|
Up to E100 with shorter lifetime
Please use within the specified limit values only.
|
|
Up to E100 with shorter lifetime
Please find further application hints in the offer drawing at our homepage.
|
Ordering Information
Fuel Pump FP 200-7
Order number: F.02U.V03.136-01
Legal Restrictions
Generally blocked are direct and indirect business involving high risk destinations, including Russia, Belarus, Cuba, Iran, North Korea, Syria, Libya, Afghanistan, and certain non-governmental controlled Ukrainian regions. This list may change as geopolitics evolve.